Product Origin:
ChinaShipping Port:
ShanghaiOrder(MOQ):
1Description
1. Ultra-wide output voltage range: 100-750V to meet the fast charging needs of various battery systems
2. Built-in intelligent discharge circuit: automatically discharges residual charge, simplifies system design, and improves system reliability
3. High efficiency in the full load range: operation in the full load range is more energy-saving than industry products that are inefficient when charging in the low load area and at full load.
4. Three-proof design: anti-salt spray, anti-moisture, anti-mildew and other protection and process design, so that the module can adapt to various charging station application scenarios
5. Wide temperature range: -40℃~+75℃, derated output above 55℃, adaptable to the application of charging piles in various scenarios
6. Portable application design: easy to integrate, easy to install, easy to assemble
7. Full digital control: DSP design realizes full digital control of the charging module to ensure high reliability of control
8. Ultra-wide input voltage range: 90Vac~280Vac, adaptable to different power grid environments
9. Strong protection ability: anti-salt spray, anti-moisture, anti-mildew and other protection and process design make the module adaptable to various charging station application scenarios
10. Battery anti-backfeed: effectively protect the battery while ensuring reliable operation of the system
11. Low standby power consumption: standby power consumption is less than 8W
12. Color LCD display, touch buttons, and human-computer interaction are more convenient
13. The system parameter setting is flexible, and the charging voltage, charging current, and charging time can be set through the LCD screen.
Application occasions:
Photovoltaic energy storage battery system, power system, DC charging station
Parameter
Model
STIN 75020S
AC input
Input phase
Single phase + PE
Voltage range
180-260Vac
Rated voltage
220Vac
Frequency range
50Hz/60Hz
Maximum current
<32A
DC output
DC Voltage range
100~750Vdc
Output power
7KW@ voltage >350VDC
Output DC current (A)
20A (1~20A adjustable)
Voltage stabilized
accuracy
<±0.5%
Current stabilized accuracy
≤±1%(output power in 20%~100%)
Load regulation rate
≤±0.5%
Grid regulation rate
≤±0.1%
Startup overshoot
≤±3%
Power factor
and THD
Power factor
≥0.95 Full-load output power of
@20%~50%
≥0.98 Full-load output power of
@50%~100%
≥0.99 Full-load output power, input
nominal voltage and frequency of
@100%
THD
≤5% Full-load output power of
@50%~100%
Efficiency
≥94.5%, @750V, 50%~100% load
current, under rated input voltage
Protection
function
input overvoltage
Protection
Over Under Voltage automatic shutdown and restart when voltage return normal
Output overvoltage
protection
Over Under Voltage automatic shutdown and restart when voltage return normal
Over-temperature
protection
Automatic shutdown. Automatic restart when the temperature return to normal
Short circuit protection
Automatic shutdown and lock, need power off to restart to unlock
Noise
≤50dB(A) (1m away)
Application place
Indoor (IP20)
Environmental
conditions
Operating temperature
-40°C ~ +75°C, derating is required when the temperature is above 55°C.
Storage temperature
-40℃ ~ +70℃
Relative humidity
≤95%RH, No condensation
Cooling way
Forced fan cooling
Altitude
2000m, derating is required when the altitude is above 2000m
Mechanical
parameters
Display
LCD
Dimensions (W*D*H)
483 ×520 ×133mm
Weight
≤19kg
The charger is an AC to DC charging module. It has the advantages of wide constant power voltage range, high efficiency, high power factor, high power density, minimal electromagnetic radiation and interference, and high reliability to meet the fast charging needs of various batteries. ,Energy saving and environmental protection.
Off-grid solar energy systems is mainly composed of photovoltaic modules, controllers, inverters, batteries and other accessories The working principle of the solar panel system is that the photovoltaic module converts light energy into direct current, and the direct current is converted into alternating current under the action of the inverter, and finally realizes the power consumption function. It can be for Home applications, Commercial applications and Industrial applications. Inverter power: 5kW AC output voltage: AC110V/120V Battery voltage: DC24V or DC48V Battery type: Gel battery or LiFePO4 battery Solar panel type: Mono or poly Compatible with grid and generator Monitor: WIFI or GPRS
The off grid solar inverter can be put outside and work without battery. Both solar panel and grid are connected to the inverter, solar is priority, grid will be backup. It is very suitable for such situation: loads work at daytime, with grid connection. Electricity bill can be saved a lot. The inverter power range can be 5kw to 500kw.
Such hybrid solar system can work as both solar on grid system and solar off grid system. It can utilize electricity price difference, charge battery at low price and discharge at high price to maximize system profit, compensate local transformer limit. It can provide back-up power supply for unstable grid, during grid failure, seamless switches to off-grid mode within 20ms to realize uninterruptable supply
The on grid solar power system converts the solar energy into electrical energy, without the storage battery, and directly sends the electrical energy to the grid through the grid-connected inverter. Inverter power: 8kW AC output voltage: three phase Solar panel type: mono or poly
Characters Transformerless with three level topology Max efficiency up to 98.6% Dual MPPT inputs accommodating wide voltage range Compact structure design Complete protection function such as anti-islanding, short circuit, overload Easy installation and free maintenance WiFi or GPRS (optional) communication Component brands Specification Model No ST17KTL ST20KTL ST25KTL DC side/Input parameters Max. DC power [W] 18500 22000 25000 Max. DC voltage [Vdc] 1000Vdc. 1000Vdc. 1000Vdc Min. System start/Shut down voltage [Vdc] 250 250 250 MPPT voltage range[Vdc] 250~850 250~850 250~850 Max. input current [A] 25A*2 25A*2 25A*2 Number of MPP trackers 2 2 2 Strings per MPP tracker 2 2 2 AC side/output parameters Nominal output power [W] 17000 20000 25000 Maximum output power [W] 18500 22000 27000 Nominal output voltage/range [V] 400V/ 280-490V(adjustable) AC grid frequency/range [Hz] 50Hz,60Hz(auto-selection) / 44Hz-55Hz; 54Hz-65Hz Maximum output current [A] 25 30 36 AC connection(with PE) 3W/N/PE 3W/N/PE 3W/N/PE Current distortion(THDi) [%] <1.5 <1.5 <1.5 Power factor [%] >99.95 >99.95 >99.95 Efficiency Maximum conversion efficiency[%] 98.5 98.6 98.8 European efficiency[%] 98.1 98.2 98.3 MPPT efficiency[%] 99.9 99.9 99.9 Safety and protection yes DC reverse-polarity protection yes Anti-islanding / Overvoltage protection yes Short circuit protection yes Leakage current protection yes Grid monitoring / Ground fault monitoring yes DC/AC side varistors(thermally protected) yes General Parameters Dimension(L/W/H)[mm] 505*525*245 Weight (kg) 37 Embedded DC Switch Optional Night power consumption[W] <0.2 Isolation type Transformerless Protection degree IP65 according to IEC60529 Operation temperature[ºC] -25 ~ 60 Cooling concept Natural convection Acoustic noise level[dB] <25 Operating altitude[m] <2000 without power derating Display Graphic LCD Communication Interface Standard WIFI; GPRS(optional) Certificates and Approvals CE-(EMC/LVD) : EN(IEC) 61000-1/-2/-3/; EN(IEC) 62109-1/-2;IEC 61727/62116;G83-3/G59-3; EN50438;VDE-0126-1-1;VDE-AR-N4105;AS4777.2;AS4777.3 Projects
Off-grid or hybrid optional 6KW inverter, Max 3pcs in parallel Grade A battery cells, up to 6000+ cycles 5.5KWh battery, Max 12pcs in parallel Easy to install, combined freely BMS & battery capacity auto-sense WiFi/GPRS remote monitoring (optional)
What is off grid system? Off-grid solar energy systems are also called stand-alone solar systems. It does not connect with Grid or called Utility. It is very popular and suitable for remote areas where there is no public power or Public power is instable.It can be for Home applications, Commercial applications and Industrial applications. The off-grid solar energy system can be 1kW/2kW/3kW/5kW/10kW/12kW/16kW/20kW/24kW/30kW/50kW/80kW/100kW/120kW/ 150kW/200kW/Customized off-gid power system Off-grid system is suitable for areas without grid-connected or unstable grid-connected power. Off grid system is usually composed of solar panels, connector, inverter, batteries and mounting system. Description of 15kW solar panel system: Inverter power: 25kW AC output voltage: AC110V/120V Battery voltage: DC24V or DC48V Battery type: Gel battery or LiFePO4 battery Solar panel type: Mono or poly Compatible with grid and generator Monitor: WIFI or GPRS